EXTON
SINGLE PHASE HEATERS (208, 240, 277 volts)
The
"EX" model is particularly suitable for installation at
the point-of-use, feeding a single outlet, being fed with deionized
water at a relatively constant temperature. The rate of flow through
the heater should be regulated so as to give the desired outlet
temperature.
The
"EX-T" series is fundamentally similar to the "EX",
except that the heaters are fitted with a CLOSE LIMIT ELECTRONIC
THERMOSTAT which is able to control the outlet temperature within
±1°F (1/2°C) when deemed necessary.
|
Dimensions:
10-3/4"H" x 5-1/4"L" x 2-7/8"W" / 27.3 cm x 13.3 cm x 7.3 cm
Weight: 5 lbs / 2.3 kg
Inlet/Outlet fitting: 5/8" compression 316 S/S
Color: White
Elements: Replacement Cartridge Insert (80% Ni, 20%)
Heater Body: Udel (engineering plastic for deionized water)
Operating Pressure: 28 psi - min / 2 bars, 150 psi - max /
10.5 bars
UL Listing: E36857 (M) |
| Model |
Volts |
Amps
per Phase |
Output
(kW) |
Flow
Rate (gal/min) |
Switch-On
Flow Rate (gal/min) |
| 65°F
RISE |
70°F
RISE |
75°F
RISE |
| EX55T |
208 |
19.7 |
4.0 |
0.42 |
|
0.4 |
| EX75T |
208 |
27.0 |
5.5 |
0.58 |
0.54 |
0.5 |
0.5 |
| EX95T |
208 |
34.0 |
7.0 |
0.75 |
0.69 |
0.65 |
0.65 |
| EX98T |
208 |
40.0 |
8.3 |
0.87 |
0.8 |
0.75 |
0.65 |
| EX55T |
240 |
23.0 |
5.5 |
0.58 |
0.54 |
0.5 |
0.4 |
| EX75T |
240 |
32.0 |
7.5 |
0.79 |
0.73 |
0.68 |
0.5 |
| EX95T |
240 |
40.0 |
9.5 |
1.00 |
0.93 |
0.86 |
0.65 |
| EX60T |
277 |
21.7 |
6.0 |
0.63 |
0.58 |
0.55 |
0.5 |
| EX80T |
277 |
28.8 |
8.0 |
0.84 |
0.78 |
0.73 |
10.65 |
| EX100T |
277 |
38.5 |
10.0 |
1.05 |
0.97 |
0.91 |
0.85 |
|
|
|
EXTON
THREE PHASE HEATERS (480/277 - 208/120 volts)
EXTON
"Three Phase DI" water heaters are of modular construction
using three standard heating modules which can either be plumbed
in series of parallel, and subject to a maximum voltage of 277 volts
across any one element, which may be electrically wired in WYE (STAR)
or DELTA configuration. This series should be used for higher rates
of flow where the single phase heaters can not produce enough water
at the required temperatures.
In
some applications, where a steady rate of flow at a constant temperature
from a deionized water supply ata constant temperature, is required,
the "EX" or "Flow Controlled" series is satisfactory.
The rise in temperature is determined by the rate of flow and the
power of the unit in accordance with the table below. Where the
supply water temperature is erratic or varying rates of flow are
required, the "EX-T" Thermostatic series will give a more
controlled performance.
The
heater must be installed ONLY IN THE VERTICAL POSITION with the
inlet/outlet fittings and electrical conduit entry at the bottom.
|
Dimensions:
12-1/4"H" x 15-1/4"L" x 4-1/4"W"L-5/8" / 31.1 cm x 38.7 cm x 10.8 cm
Weight: 15 lbs / 6.8 kg
Inlet/Outlet Fitting: 5/8" compression 316 S/S
Elements: Replacement Cartridge Insert (80% Ni, 20% Cr element
wire)
Heater Body: Udel (engineering plastic for deionized water)
Operating Pressure: 28 psi - min / 2 bars, 150 psi - max /
10.5 bars
UL Listing: E86887 (M)
U.S. Patent No: 4.762.980 |
| Model |
Volts |
Amps
per Phase |
Output
(kW) |
Flow
Rate (gal/min) |
Switch-On
Flow Rate (gal/min) |
| 65°F
RISE |
70°F
RISE |
75°F
RISE |
| EX180T |
208 |
50 |
18 |
1.89 |
1.76 |
1.64 |
1.5 |
| EX240T |
208 |
67 |
24 |
2.52 |
2.34 |
2.18 |
1.9 |
| EX320T |
277 |
38.5 |
32 |
3.36 |
3.12 |
2.91 |
2.5 |
| EX180T |
277 |
22 |
18 |
1.89 |
1.76 |
1.64 |
1.5 |
| EX240T |
277 |
29 |
24 |
2.52 |
2.34 |
2.18 |
1.9 |
|
|
|
EXTON
INTERNATIONAL
(220 volts) - Single Phase Unit
(380/220 volts) - Three Phase Unit
Pressure:
2 bar min, 10 bar max
Fittings: 5/8" compression 316 S/S
Heater Body: Udel (engineering plastic for deionized water)
Weight: 2.3 kg (single phase), 6.8 kg (three phase)
Dimensions (single phase): 13.3 cm H x 27.3 cm L x 7.3 cm W
Dimensions (three phase): 31.1 cm H x 38.7 L cm x 10.8 cm W
|
| Model |
Volts |
Amps
per Phase |
Output
(kW) |
Flow
Rate LPM |
Switch-On
Flow Rate |
| 35°C
RISE |
40°C
RISE |
45°C
RISE |
| EX55T |
220 |
25 |
5.5
|
2.2 |
2.0 |
1.9 |
1.5 |
| EX66T |
220 |
30 |
6.6 |
2.6 |
2.4 |
2.2 |
1.9 |
| EX77T |
220 |
35 |
7.7 |
3.0 |
2.8 |
2.6 |
2.3 |
| EX88T |
220 |
40 |
8.8
|
3.5 |
3.2 |
3.0 |
2.5 |
|
|
|
|
|
|
|
|
| EX165T |
380/220 |
25 |
16.5 |
6.6 |
6.0 |
5.6 |
4.5 |
| EX198T |
380/220 |
30 |
19.8 |
7.9 |
7.3 |
6.8 |
5.7 |
| EX231T |
380/220 |
35 |
23.1 |
9.2 |
8.5 |
7.9 |
7.2 |
| EX264T |
380/220 |
40 |
26.4 |
10.5 |
9.7 |
9.0 |
7.5 |
|
|
|
Typical
Installation Diagram 1
Typical
Installation Diagram 2
Typical
Installation Diagram 3
Selecting
the correct heater(s) for your application(s)
Main