EXTON SINGLE PHASE HEATERS (208, 240, 277 volts)

The "EX" model is particularly suitable for installation at the point-of-use, feeding a single outlet, being fed with deionized water at a relatively constant temperature. The rate of flow through the heater should be regulated so as to give the desired outlet temperature.

The "EX-T" series is fundamentally similar to the "EX", except that the heaters are fitted with a CLOSE LIMIT ELECTRONIC THERMOSTAT which is able to control the outlet temperature within ±1°F (1/2°C) when deemed necessary.

Dimensions:
10-3/4"H" x 5-1/4"L" x 2-7/8"W" / 27.3 cm x 13.3 cm x 7.3 cm
Weight: 5 lbs / 2.3 kg
Inlet/Outlet fitting: 5/8" compression 316 S/S
Color: White
Elements: Replacement Cartridge Insert (80% Ni, 20%)
Heater Body: Udel (engineering plastic for deionized water)
Operating Pressure: 28 psi - min / 2 bars, 150 psi - max / 10.5 bars
UL Listing: E36857 (M)
Model Volts Amps per Phase Output (kW) Flow Rate (gal/min) Switch-On Flow Rate (gal/min)
65°F RISE 70°F RISE 75°F RISE
EX55T 208 19.7 4.0 0.42   0.4
EX75T 208 27.0 5.5 0.58 0.54 0.5 0.5
EX95T 208 34.0 7.0 0.75 0.69 0.65 0.65
EX98T 208 40.0 8.3 0.87 0.8 0.75 0.65
EX55T 240 23.0 5.5 0.58 0.54 0.5 0.4
EX75T 240 32.0 7.5 0.79 0.73 0.68 0.5
EX95T 240 40.0 9.5 1.00 0.93 0.86 0.65
EX60T 277 21.7 6.0 0.63 0.58 0.55 0.5
EX80T 277 28.8 8.0 0.84 0.78 0.73 10.65
EX100T  277 38.5 10.0 1.05 0.97 0.91 0.85

EXTON THREE PHASE HEATERS (480/277 - 208/120 volts)

EXTON "Three Phase DI" water heaters are of modular construction using three standard heating modules which can either be plumbed in series of parallel, and subject to a maximum voltage of 277 volts across any one element, which may be electrically wired in WYE (STAR) or DELTA configuration. This series should be used for higher rates of flow where the single phase heaters can not produce enough water at the required temperatures.

In some applications, where a steady rate of flow at a constant temperature from a deionized water supply ata constant temperature, is required, the "EX" or "Flow Controlled" series is satisfactory. The rise in temperature is determined by the rate of flow and the power of the unit in accordance with the table below. Where the supply water temperature is erratic or varying rates of flow are required, the "EX-T" Thermostatic series will give a more controlled performance.

The heater must be installed ONLY IN THE VERTICAL POSITION with the inlet/outlet fittings and electrical conduit entry at the bottom.

Dimensions:
12-1/4"H" x 15-1/4"L" x 4-1/4"W"L-5/8" / 31.1 cm x 38.7 cm x 10.8 cm
Weight: 15 lbs / 6.8 kg
Inlet/Outlet Fitting: 5/8" compression 316 S/S
Elements: Replacement Cartridge Insert (80% Ni, 20% Cr element wire)
Heater Body: Udel (engineering plastic for deionized water)
Operating Pressure: 28 psi - min / 2 bars, 150 psi - max / 10.5 bars
UL Listing: E86887 (M)
U.S. Patent No: 4.762.980
Model Volts Amps per Phase Output (kW) Flow Rate (gal/min) Switch-On Flow Rate (gal/min)
65°F RISE 70°F RISE 75°F RISE
EX180T  208 50 18 1.89 1.76 1.64 1.5
EX240T 208 67 24 2.52 2.34 2.18 1.9
EX320T 277 38.5 32 3.36 3.12 2.91 2.5
EX180T 277 22 18 1.89 1.76 1.64 1.5
EX240T 277 29 24 2.52 2.34 2.18 1.9

EXTON INTERNATIONAL
(220 volts) - Single Phase Unit
(380/220 volts) - Three Phase Unit

Pressure: 2 bar min, 10 bar max
Fittings: 5/8" compression 316 S/S
Heater Body: Udel (engineering plastic for deionized water)
Weight: 2.3 kg (single phase), 6.8 kg (three phase)
Dimensions (single phase): 13.3 cm H x 27.3 cm L x 7.3 cm W
Dimensions (three phase): 31.1 cm H x 38.7 L cm x 10.8 cm W

Model Volts Amps per Phase Output (kW) Flow Rate LPM Switch-On Flow Rate
35°C RISE 40°C RISE 45°C RISE
EX55T 220 25 5.5 2.2 2.0 1.9 1.5
EX66T 220 30 6.6 2.6 2.4 2.2 1.9
EX77T 220 35 7.7 3.0 2.8 2.6 2.3
EX88T 220 40 8.8 3.5 3.2 3.0 2.5
EX165T  380/220 25 16.5 6.6 6.0 5.6 4.5
EX198T 380/220 30 19.8 7.9 7.3 6.8 5.7
EX231T 380/220 35 23.1 9.2 8.5 7.9 7.2
EX264T 380/220 40 26.4 10.5 9.7 9.0 7.5

Typical Installation Diagram 1

Typical Installation Diagram 2

Typical Installation Diagram 3

Selecting the correct heater(s) for your application(s)

Main Page